Site Accessibility Evaluation

Greanleaf Park
1598 Rose Hill Dr
Barracks Rugby, VA 22903
Inspection Date: 11/14/2023
Inspectors: Brandon Hill
Prepared By
Precision Infrastructure Management
(800) 734 - 8891
www.PrecisionInfrastructureMgmt.com
Report Date: 09/23/2024

Findings

Trails : Primary trail

Finding: 1

There is no accessible route to the accessible element.

At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site.
Citation:
2010 ADAS Section 206.2.2
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site.

Recommendation:
create accessible route to trailhead. capital investment
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834262 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 2

The path of contains multiple issues and is not accessible.

Signage: none provided
Length: unstated
Material: asphalt, gravel; natural
Average width: 5’
Minimum width: 3’
Max slope: 25%
Max cross slope: 17.5%

The path of travel exceeds the maximum allowable cross and running slope requirements. It also contains changes in level and/or gaps that exceed the allowable maximum requirements. The floor or ground surface is not firm, stable, and slip resistant.
Citation:
2010 ADAS Section 403.1
Walking surfaces that are a part of an accessible route shall comply with 403.

Recommendation:
Cut or grind VHDs; repave route
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834263 Main Photo
Additional Finding Photos
Finding 834263 Additional Photo
Finding 834263 Additional Photo
Finding 834263 Additional Photo
Finding 834263 Additional Photo
Finding 834263 Additional Photo
Finding 834263 Additional Photo
Finding 834263 Additional Photo
Finding 834263 Additional Photo
Finding 834263 Additional Photo
Finding 834263 Additional Photo
Finding 834263 Additional Photo

Playground: Playground

Finding: 3

The transfer space is sloped greater than 2%.

Floor or ground surfaces of a clear floor or ground space shall not have changes in level. Slopes not steeper than 1:48 shall be permitted.
Citation:
2010 ADAS Section 305.2
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted.

2010 ADAS Section 1008.3.1.3
A transfer space complying with 305.2 and 305.3 shall be provided adjacent to the transfer platform. The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform. The side of the transfer platform serving the transfer space shall be unobstructed.

Recommendation:
Level and maintain surface, or replace with alternative compliant surface
Barrier Priority:
Low (4): Should be completed as soon as possible due to being a technical violation, but may not result in providing greater access to persons with disabilities. (Includes; Findings that are technically violations but provide a moderate to low increase in accessibility compared to the financial impact on the entity)
Finding 834251 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 4

The transfer platform has not been provided with support for transferring.

Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided.
Citation:
2010 ADAS Section 1008.3.1.4
At least one means of support for transferring shall be provided.

Recommendation:
Install compliant transfer system
Barrier Priority:
Low (4): Should be completed as soon as possible due to being a technical violation, but may not result in providing greater access to persons with disabilities. (Includes; Findings that are technically violations but provide a moderate to low increase in accessibility compared to the financial impact on the entity)
Finding 834252 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 5

Compliance with ASTM F1951 for accessibility for ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces has not been determined.

Ground surfaces shall comply with ASTM F 1951. Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951.
Citation:
2010 ADAS Section 1008.2.6.1
Ground surfaces shall comply with ASTM F 1951 (incorporated by reference, see "Referenced Standards" in Chapter 1). Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951.

Recommendation:
Maintain existing surface or replace with alternate compliant material
Barrier Priority:
Low (4): Should be completed as soon as possible due to being a technical violation, but may not result in providing greater access to persons with disabilities. (Includes; Findings that are technically violations but provide a moderate to low increase in accessibility compared to the financial impact on the entity)
Finding 834255 Main Photo

Playground: Accessible Route

Finding: 6

The curb ramp exceeds the maximum running slope (parallel to the direction of travel) allowable of 8.33%.

Curb ramps should have the least possible slope but in no case more than 8.33% (1:12).
Citation:
2010 ADAS Section 406.1
Curb ramps on accessible routes shall comply with 406, 405.2 through 405.5, and 405.10.

Recommendation:
Replace curb ramp
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834244 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 7

The curb ramp on the accessible route has cross slopes greater than 2%.

Surface cross slopes shall not exceed one unit vertical in 48 units horizontal (2-percent slope).
Citation:
2010 ADAS Section 405.3
Cross slope of ramp runs shall not be steeper than 1:48.

2010 ADAS Section 406.1
Curb ramps on accessible routes shall comply with 406, 405.2 through 405.5, and 405.10.

Recommendation:
Replace curb ramp
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834245 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 8

The change in level where the gutter meets the curb ramp is greater than 1/4 inch.

1/4 inch is the maximum vertical rise. Changes in level between 1/4 inch and 1/2 inch must be beveled at 1:2 or less. Changes in level greater than 1/2 inch must be by way of a ramp.
Citation:
2010 ADAS Section 303.3
Changes in level between 1/4 inch (6.4 mm) high minimum and 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.

Recommendation:
Replace curb ramp
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834246 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 9

The landing of the ramp has a slope greater than 2 percent.

Landings shall have a slope of less than 1:48 (2 percent) in any direction.
Citation:
2010 ADAS Section 406.4
Landings shall be provided at the tops of curb ramps. The landing clear length shall be 36 inches (915 mm) minimum. The landing clear width shall be at least as wide as the curb ramp, excluding flared sides, leading to the landing.

2010 ADAS Section 406.4 Exception
In alterations, where there is no landing at the top of curb ramps, curb ramp flares shall be provided and shall not be steeper than 1:12.

Recommendation:
Level and replace landing
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834247 Main Photo

Finding: 10

The curb ramp side flares exceed maximum slope allowances.

The sides of curb ramps (curb ramp flares) where provided, shall not be steeper than 1:10.
Citation:
2010 ADAS Section 406.3
Where provided, curb ramp flares shall not be steeper than 1:10.

Recommendation:
Replace curb ramp
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834248 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 11

The path of contains multiple issues and is not accessible.

The path of travel exceeds the maximum allowable cross slope requirements. It also contains changes in level and/or gaps that exceed the allowable maximum requirements.
Citation:
2010 ADAS Section 403.1
Walking surfaces that are a part of an accessible route shall comply with 403.

Recommendation:
Cut or grind VHDs; replace affected panels
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834257 Main Photo
Additional Finding Photos
Finding 834257 Additional Photo
Finding 834257 Additional Photo

Washrooms : Men's room

Finding: 12

The wall sign is mounted too high.

Tactile Characters on signs shall be located 48 inches minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character. Mounting location shall be determined so that a person may approach within 3 inches of signage without encountering protruding objects and shall be located so that a clear floor space of 18 inches minimum by 18 inches minimum, centered on the tactile Characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position.
Citation:
2010 ADAS Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character.

Recommendation:
Reduce sign height to compliant range
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834221 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 13

There is not enough clear floor space at the water closet.

Clear floor space around the water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall. No other fixture is allowed in this space.
Citation:
2010 ADAS Section 604.3.1
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall.

Recommendation:
Reconfigure restroom. Capital investment
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834223 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 14

The toilet paper is not installed within the compliant range in front of the toilet.

Toilet paper dispensers shall be 7 inches minimum and 9 inches maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be 15 inches minimum and 48 inches maximum above the finish floor and shall not be located behind grab bars. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. There shall be a clearance of 1 1/2 inches minimum below the grab bar.
Citation:
2010 ADAS Section 604.7
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow.

Recommendation:
Move dispenser to compliant range
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834224 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 15

The element is positioned less than 12 inches from the top of the grab bar.

Elements adjacent to the grab bar shall be positioned to provide unobstructed use of grab bars. The space between the grab bar and projecting objects below and at the ends shall be 1-1/2 inches minimum. The space between the grab bar and projecting objects above shall be 12 inches minimum.
Citation:
2010 ADAS Section 609.3
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1 1/2 inches (38 mm) minimum. The space between the grab bar and projecting objects above shall be 12 inches (305 mm) minimum.

Recommendation:
Move dispenser to compliant location
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834225 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 16

The rear grab bar does not extend adequately past the toilet on the wide side.

The rear grab bar must be a minimum of 36 inches long and extend from the centerline of the toilet 12 inches minimum on wall side and 24 inches minimum on the wide side.

Grab bars shall be installed in a horizontal position, 33 inches minimum and 36 inches maximum above the finish floor measured to the top of the gripping surface and the space between the grab bar and the top of the tank shall be 1-1/2 inches minimum.
Citation:
2010 ADAS Section 604.5.2
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on the other side.

Recommendation:
Move grab bar to compliant location
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834226 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 17

The clear floor space between the lavatory and the toilet is too narrow.

The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space and clearances required at other fixtures, and the turning space. No other fixtures or obstructions shall be located within the required water closet clearance.

Clear floor space around the water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall.
Citation:
2010 ADAS Section 604.3.2
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space and clearances required at other fixtures, and the turning space. No other fixtures or obstructions shall be located within the required water closet clearance.

Recommendation:
Reconfigure washroom. Capital investment
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834227 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 18

The lavatory's clear floor space is not a minimum 30 inches wide by 48 inches deep.

A 30 inch by 48 inch clear floor space positioned for a forward approach with knee and toe clearance shall be provided.
Citation:
2010 ADAS Section 606.2
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided.

Recommendation:
Move trash can to compliant location
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834228 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 19

The clear floor space required at the element is not flat (2% or 1:48 maximum slope) in all directions.

Changes in level are not permitted at required clear floor or ground space except that slopes not steeper than 1:48 shall be permitted.
Citation:
2010 ADAS Section 305.2
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted.

Recommendation:
Level and re-pour around floor drain
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834229 Main Photo

Finding: 20

The water and drain pipes under the lavatory are not adequately insulated.

Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories and sinks.
Citation:
2010 ADAS Section 606.5
Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories and sinks.

Recommendation:
Install insulation kit
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834230 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 21

The soap dispenser is out of reach range because the depth of the obstruction is greater than 25 inches.

Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the reach depth over the obstruction. Where the reach depth exceeds 20 inches, the high forward reach shall be 44 inches maximum and the reach depth shall be 25 inches maximum.
Citation:
2010 ADAS Section 308.2.2
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48 inches (1220 mm) maximum where the reach depth is 20 inches (510 mm) maximum. Where the reach depth exceeds 20 inches (510 mm), the high forward reach shall be 44 inches (1120 mm) maximum and the reach depth shall be 25 inches (635 mm) maximum.

Recommendation:
Move dispenser to compliant location
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834231 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 22

The door is equipped with a door closer and returns to a closed position too quickly.

Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
Citation:
2010 ADAS Section 404.2.8.1
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.

Recommendation:
Adjust or replace closer
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834232 Main Photo
Image that depicts the citation requirements of the code or standard

Washrooms : Women's room

Finding: 23

The wall sign is mounted too high.

Tactile Characters on signs shall be located 48 inches minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character. Mounting location shall be determined so that a person may approach within 3 inches of signage without encountering protruding objects and shall be located so that a clear floor space of 18 inches minimum by 18 inches minimum, centered on the tactile Characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position.
Citation:
2010 ADAS Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character.

Recommendation:
Move sign to compliant height range
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834220 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 24

The door is equipped with a door closer and returns to a closed position too quickly.

Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
Citation:
2010 ADAS Section 404.2.8.1
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.

Recommendation:
Adjust or replace closer
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834233 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 25

The element projects more than 4 inches into the circulation path.

Wall-mounted objects that have leading edges between 27 inches and 80 inches from the floor must not project more than 4 inches into the circulation path. Protruding objects that extend to the floor or within 27 inches of the floor are cane detectable and are therefore not hazardous. Where it is necessary or desirable to have objects protrude from the wall, a manner of cane detection must be provided.
Citation:
2010 ADAS Section 307.2
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path.

Recommendation:
Remove vestigial dispenser
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834234 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 26

There is not enough clear floor space at the water closet.

Clear floor space around the water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall. No other fixture is allowed in this space.
Citation:
2010 ADAS Section 604.3.1
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall.

Recommendation:
Reconfigure restroom. Capital investment
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834235 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 27

The toilet paper is not installed within the compliant range in front of the toilet.

Toilet paper dispensers shall be 7 inches minimum and 9 inches maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be 15 inches minimum and 48 inches maximum above the finish floor and shall not be located behind grab bars. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. There shall be a clearance of 1 1/2 inches minimum below the grab bar.
Citation:
2010 ADAS Section 604.7
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow.

Recommendation:
Move dispenser to compliant location
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834236 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 28

The element is positioned less than 12 inches from the top of the grab bar.

Elements adjacent to the grab bar shall be positioned to provide unobstructed use of grab bars. The space between the grab bar and projecting objects below and at the ends shall be 1-1/2 inches minimum. The space between the grab bar and projecting objects above shall be 12 inches minimum.
Citation:
2010 ADAS Section 609.3
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1 1/2 inches (38 mm) minimum. The space between the grab bar and projecting objects above shall be 12 inches (305 mm) minimum.

Recommendation:
Move dispenser to compliant location
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834237 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 29

The rear grab bar does not extend adequately past the toilet on the wide side.

The rear grab bar must be a minimum of 36 inches long and extend from the centerline of the toilet 12 inches minimum on wall side and 24 inches minimum on the wide side.

Grab bars shall be installed in a horizontal position, 33 inches minimum and 36 inches maximum above the finish floor measured to the top of the gripping surface and the space between the grab bar and the top of the tank shall be 1-1/2 inches minimum.
Citation:
2010 ADAS Section 604.5.2
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on the other side.

Recommendation:
Move grab bar to compliant range
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834238 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 30

The clear floor space between the lavatory and the toilet is too narrow.

The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space and clearances required at other fixtures, and the turning space. No other fixtures or obstructions shall be located within the required water closet clearance.

Clear floor space around the water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall.
Citation:
2010 ADAS Section 604.3.2
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space and clearances required at other fixtures, and the turning space. No other fixtures or obstructions shall be located within the required water closet clearance.

Recommendation:
Reconfigure restroom. Capital investment
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834239 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 31

The clear floor space required at the element is not flat (2% or 1:48 maximum slope) in all directions.

Changes in level are not permitted at required clear floor or ground space except that slopes not steeper than 1:48 shall be permitted.
Citation:
2010 ADAS Section 305.2
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted.

Recommendation:
Level and re-pour around floor drain
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834240 Main Photo

Finding: 32

The water and drain pipes under the lavatory are not adequately insulated.

Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories and sinks.
Citation:
2010 ADAS Section 606.5
Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories and sinks.

Recommendation:
Install insulation kit
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834241 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 33

The soap dispenser is out of reach range because the depth of the obstruction is greater than 25 inches.

Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the reach depth over the obstruction. Where the reach depth exceeds 20 inches, the high forward reach shall be 44 inches maximum and the reach depth shall be 25 inches maximum.
Citation:
2010 ADAS Section 308.2.2
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48 inches (1220 mm) maximum where the reach depth is 20 inches (510 mm) maximum. Where the reach depth exceeds 20 inches (510 mm), the high forward reach shall be 44 inches (1120 mm) maximum and the reach depth shall be 25 inches (635 mm) maximum.

Recommendation:
Move dispenser to compliant location
Barrier Priority:
Moderate (3): Should be completed as soon as possible, but there may be other items that will provide greater access to persons with disabilities. (Includes; Findings that have a high financial impact on the entity in relationship to the degree of access provided)
Finding 834242 Main Photo
Image that depicts the citation requirements of the code or standard

Washrooms : Accessible route

Finding: 34

The path of contains multiple issues and is not accessible.

The path of travel exceeds the maximum allowable cross and running slope requirements. It also contains changes in level and/or gaps that exceed the allowable maximum requirements.
Citation:
2010 ADAS Section 403.1
Walking surfaces that are a part of an accessible route shall comply with 403.

Recommendation:
Cut or grind VHDs; Replace affected panels, capital investment
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834218 Main Photo
Additional Finding Photos
Finding 834218 Additional Photo
Finding 834218 Additional Photo
Finding 834218 Additional Photo
Finding 834218 Additional Photo
Finding 834218 Additional Photo
Finding 834218 Additional Photo

Finding: 35

The required types of drinking fountains are not provided.

Where drinking fountains are provided, a minimum of one must be designed for wheelchair users and one must be designed for standing persons unless a single fountain meets the requirements for both.
Citation:
2010 ADAS Section 211.2
No fewer than two drinking fountains shall be provided. One drinking fountain shall comply with 602.1 through 602.6 and one drinking fountain shall comply with 602.7.

Recommendation:
Install second, standing fountain
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834219 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 36

The water fountain projects into the headroom clearance in the circulation path.

Wall-mounted objects that have leading edges between 27 inches and 80 inches from the floor must not project more than 4 inches into the circulation path. Protruding objects that extend to the floor or within 27 inches of the floor are cane detectable and are therefore not hazardous. Where it is necessary or desirable to have objects protrude from the wall, a manner of cane detection must be provided.
Citation:
2010 ADAS Section 307.2
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path.

Recommendation:
Install edge protection
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834261 Main Photo
Image that depicts the citation requirements of the code or standard

Basketball court: Basketball court

Finding: 37

The walkway contains abrupt vertical edges and/or variations over 1/4 inch.

1/4 inch is the maximum vertical rise. Changes in level between 1/4 inch and 1/2 inch must be beveled at 1:2 or less.

Changes in level greater than 1/2 inch must be by way of a ramp.
Citation:
2010 ADAS Section 303.3
Changes in level between 1/4 inch (6.4 mm) high minimum and 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.

2010 ADAS Section 303.2
Changes in level of 1/4 inch (6.4 mm) high maximum shall be permitted to be vertical.

Recommendation:
Cut or grind VHD; replace affected panels
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834260 Main Photo
Image that depicts the citation requirements of the code or standard

Shelter: Accessible route

Finding: 38

The path of contains multiple issues and is not accessible.

The path of travel exceeds the maximum allowable cross slope requirements. It also contains changes in level and/or gaps that exceed the allowable maximum requirements.
Citation:
2010 ADAS Section 403.1
Walking surfaces that are a part of an accessible route shall comply with 403.

Recommendation:
Cut or grind VHDs; replace affected panels
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834258 Main Photo
Additional Finding Photos
Finding 834258 Additional Photo
Finding 834258 Additional Photo
Finding 834258 Additional Photo

Finding: 39

There is no accessible route to the accessible element.

At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site.
Citation:
2010 ADAS Section 206.2.2
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site.

Recommendation:
Move grill onto route or create route
Barrier Priority:
Important (2): Should be completed as soon as possible. (Includes; Findings that would remove barriers to the greatest number of people to your goods and services)
Finding 834259 Main Photo
Image that depicts the citation requirements of the code or standard

Parking: Parking lot

Finding: 40

There are no van accessible parking stalls.

1 in every 6, minimum of one, required accessible stalls must be a van accessible stall.

There are a total of 24 parking stalls in the parking lot that could be reasonably associated with this facility. There should be a minimum of 1 accessible stalls with a minimum of 1 being designed as van accessible.
Citation:
2010 ADAS Section 208.2
Parking spaces complying with 502 shall be provided in accordance with Table 208.2 except as required by 208.2.1, 208.2.2, and 208.2.3. Where more than one parking facility is provided on a site, the number of accessible spaces provided on the site shall be calculated according to the number of spaces required for each parking facility.

2010 ADAS Section 208.2.4
For every six or fraction of six parking spaces required by 208.2 to comply with 502, at least one shall be a van parking space complying with 502.

Recommendation:
Designate compliant van stall
Barrier Priority:
Low (4): Should be completed as soon as possible due to being a technical violation, but may not result in providing greater access to persons with disabilities. (Includes; Findings that are technically violations but provide a moderate to low increase in accessibility compared to the financial impact on the entity)
Finding 834215 Main Photo
Image that depicts the citation requirements of the code or standard

Parking: Accessible space

Finding: 41

The cross slopes (narrow dimension) and/or running slopes (long dimension) of the accessible stall exceeds 2%.

The running slope and the cross slope in an accessible parking stall and the access aisle must not exceed 2%.
Citation:
2010 ADAS Section 502.4
Parking spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted.

Recommendation:
Repave and repaint stall
Barrier Priority:
Low (4): Should be completed as soon as possible due to being a technical violation, but may not result in providing greater access to persons with disabilities. (Includes; Findings that are technically violations but provide a moderate to low increase in accessibility compared to the financial impact on the entity)
Finding 834216 Main Photo
Image that depicts the citation requirements of the code or standard

Finding: 42

The cross slopes (narrow dimension) and/or running slopes (long dimension) of the access aisle exceeds 2%.

The running slope and the cross slope in an accessible parking stall and the access aisle must not exceed 2%.
Citation:
2010 ADAS Section 502.4
Parking spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted.

Recommendation:
Repave and repaint
Barrier Priority:
Low (4): Should be completed as soon as possible due to being a technical violation, but may not result in providing greater access to persons with disabilities. (Includes; Findings that are technically violations but provide a moderate to low increase in accessibility compared to the financial impact on the entity)
Finding 834217 Main Photo
Image that depicts the citation requirements of the code or standard